中開泵業水泵行業各種管路損耗參考表
本文由長沙水泵廠家中開泵業整理。因為管路的損耗對泵的選型有著很大的影響。希望文章相關大小管徑對應了損耗內容能對大家有點幫助。
管徑(mm)
|
25
|
38
|
50
|
65
|
75
|
100
|
125
|
150
|
175
|
200
|
250
|
300
|
|
流量(L/S)
|
1
|
3.27
|
3.5
|
0.8
|
|
|
|
|
|
|
|
|
|
2
|
13.0
|
14
|
3.1
|
0.8
|
0.4
|
|
|
|
|
|
|
|
|
4
|
|
55
|
13
|
3.2
|
1.6
|
0.4
|
|
|
|
|
|
|
|
6
|
|
|
29
|
7.1
|
3.3
|
0.8
|
0.23
|
|
|
|
|
|
|
8
|
|
|
|
13
|
5.9
|
1.3
|
0.4
|
0.16
|
|
|
|
|
|
10
|
|
|
|
20
|
9.6
|
2.1
|
0.63
|
0.26
|
0.11
|
|
|
|
|
|
|
15
|
|
|
21.6
|
6.8
|
1.3
|
0.58
|
0.27
|
0.13
|
|
|
|
|
|
20
|
|
|
|
8.6
|
2.7
|
1.1
|
0.5
|
0.26
|
0.07
|
|
|
|
|
|
25
|
|
|
13
|
4.1
|
1.6
|
0.74
|
0.37
|
0.12
|
|
|
|
|
|
30
|
|
|
19.4
|
5.9
|
2.3
|
1.05
|
0.53
|
0.18
|
0.07
|
|
|
|
|
|
40
|
|
|
10.7
|
4.2
|
1.9
|
0.93
|
0.30
|
0.12
|
|
|
|
|
|
50
|
|
|
|
6.4
|
2.9
|
1.5
|
0.48
|
0.19
|
|
|
|
|
|
|
60
|
|
|
9.4
|
4.3
|
2.1
|
0.68
|
0.27
|
|
|
|
|
|
|
70
|
|
|
|
5.8
|
2.9
|
0.93
|
0.37
|
|
|
|
|
|
|
|
80
|
|
|
7.7
|
3.7
|
1.2
|
0.49
|
|
|
|
|
|
|
|
90
|
|
|
9.6
|
4.7
|
1.5
|
0.6
|
|
|
|
|
|
|
|
|
100
|
|
|
6.1
|
1.9
|
0.76
|
|
|
|
|
|
|
|
|
110
|
|
|
7.2
|
2.3
|
0.9
|
|
|
|
|
|
|
|
|
|
120
|
|
8.5
|
2.8
|
1.1
|
|
|
|
|
|
|
|
|
|
130
|
|
|
3.3
|
1.3
|
|
直管摩擦損失表(供估計用)
管100m直管損失米數
(以新鑄管為標準,舊管加倍)
|
140
|
|
3.7
|
1.5
|
|||||||||
160
|
|
4.9
|
2.0
|
||||||||||
|
180
|
5.2
|
2.4
|
||||||||||
|
200
|
|
3.0
|
閥及彎管折合直管長度(每個)
|
||
種類
|
折合直管直徑倍數
|
備注
|
全開閘閥
|
12
|
未暢開加倍
|
標準彎管
|
25
|
|
逆止閥
|
100
|
|
底閥
|
100
|
部分堵塞加倍
|
一定管路直徑之最大流量限制
|
|||||
管路直徑(mm)
|
最大流量(L/S)
|
最大流速(m/s)
|
管路直徑(mm)
|
最大流量(L/S)
|
最大流速(m/s)
|
25
|
1
|
2.04
|
125
|
30.0
|
2.44
|
38
|
2.5
|
1.69
|
150
|
43.0
|
2.45
|
50
|
4.17
|
2.12
|
175
|
60.0
|
2.49
|
65
|
6.67
|
2.01
|
200
|
83.3
|
2.69
|
75
|
10.0
|
2.26
|
250
|
133.3
|
2.72
|
100
|
18.4
|
2.33
|
300
|
192.0
|
2.71
|
上一條:轉向助力泵的使用與維修 下一條:談單體泵的百科知識
站內查找
版權所有:長沙水泵廠湖南中開泵業(長一制泵) 專注工業流體輸送30年
地址:長沙市岳麓區望月湖街道江岸錦城小區7棟1樓郵箱:516558583@qq.com